Serving Nacogdoches & East Texas Mon–Fri 8am–5pm
Armor Insulation of East Texas Armor Insulationof East Texas
Home/Services/Thermal Protection

Fire-protective coatings over spray foam

Spray foam is a building material — and code says it can't be left exposed in most living and working spaces. We apply intumescent barrier coatings like DC315 and No-Burn over the foam — or install FireStable™, a spray foam that's its own code-complying fire barrier. Either way your insulation ends up protected, code-compliant, and safe — a service almost no one in East Texas offers.

Why it's required

Exposed foam needs a barrier — that's code

Building codes (IBC and IRC) require spray polyurethane foam to be separated from occupied spaces by an approved thermal barrier or, in some areas, an ignition barrier. Left bare in a shop, attic, garage, or crawlspace, exposed foam can be a code violation — and a fire risk.

An intumescent coating is the approved, cost-effective way to meet that requirement. It's a water-based coating that, in a fire, swells into a thick insulating char that slows the spread of flame, smoke, and hot gases across the foam.

  • Code-compliant barrier — an approved thermal & ignition barrier over SPF.
  • Slows flame spread — intumescent char shields the foam and buys time.
  • Passes inspection — the clean way to keep exposed foam and stay legal.
Exposed spray foam before a fire-protective coating Protective coating over foam
The products we apply

DC315 & No-Burn intumescent coatings

Two of the most widely code-approved intumescent barrier coatings for spray foam. We apply them to spec, at the right thickness, so they perform and pass.

DC315

A water-based intumescent coating approved as an alternative thermal and ignition barrier over spray foam. Meets IBC/IRC code with testing behind NFPA, ASTM, UL and more.

No-Burn

An intumescent fire-protective coating for foam and building materials, applied as a code-compliant barrier that slows ignition and flame spread.

An honest note on "fireproofing"

No coating makes a building fireproof. Intumescent coatings are tested, code-recognized fire-protective barriers: they protect the foam and slow the spread of fire so people have more time to respond. Requirements vary by building and jurisdiction — we'll apply what your project actually needs and what your inspector will approve.

FireStable self-protecting spray foam applied in a metal building FireStable™ 2.0 · in the field
Featured system FireStable Insulation Company

Fire protection built into the foam

DC315 and No-Burn go on top of the foam. FireStable™ 2.0 builds the protection in. It's a two-component, spray-applied polyurethane foam that's also a code-complying thermal barrier on its own — so you get insulation, an air barrier, a vapor retarder, and fire protection in a single step, with no separate coating required.

  • Barrier and foam in one — a code-complying thermal barrier with no added coating (per NFPA 275).
  • Up to R-5 per inch — real insulation value while it protects.
  • Saves work, cost & time — one application does the job of several.

FireStable™ is a product of Firestable Insulation Company. firestable.com

Who needs it

If you can see the foam, you probably need this

  • Shops, garages, and barndominiums with exposed foam walls or ceilings
  • Attics and crawlspaces insulated with open- or closed-cell foam
  • Commercial and metal buildings where foam is left uncovered
  • Any SPF job that has to pass a code inspection

Already have foam that was left bare? We can come coat it. Doing a new foam job with us? We'll build the barrier coating into the quote from the start.

Coated, code-compliant spray foam interior Coated foam interior
Free, no-pressure estimate

Ready to make your home or shop more comfortable?

Tell us about your space and we'll give you an honest recommendation and a written quote — no obligation.